16d3b7767e
apple / swift (push) Successful in 54s
rpm / build-publish (bazzite, punktfunk-fedora-rpm) (push) Has been cancelled
rpm / build-publish (fedora-44, punktfunk-fedora44-rpm) (push) Has been cancelled
windows-host / package (push) Failing after 6m18s
android / android (push) Failing after 2m12s
ci / web (push) Successful in 38s
ci / rust (push) Failing after 1m40s
ci / docs-site (push) Successful in 29s
deb / build-publish (push) Successful in 2m35s
decky / build-publish (push) Successful in 24s
ci / bench (push) Successful in 4m32s
docker / build-push (., web/Dockerfile, punktfunk-web) (push) Successful in 14s
docker / build-push (--build-arg FEDORA_VERSION=44, ci, ci/fedora-rpm.Dockerfile, punktfunk-fedora44-rpm) (push) Successful in 3m35s
docker / build-push (ci, ci/rust-ci.Dockerfile, punktfunk-rust-ci) (push) Successful in 4s
docker / build-push (docs-site, docs-site/Dockerfile, punktfunk-docs) (push) Successful in 20s
docker / build-push (ci, ci/fedora-rpm.Dockerfile, punktfunk-fedora-rpm) (push) Successful in 2m33s
docker / deploy-docs (push) Successful in 22s
MSIX (the client's format) can't install the host's LocalSystem secure-desktop service or the SudoVDA kernel driver, so the host ships as a signed Inno Setup setup.exe that runs elevated and delegates to the existing idempotent `punktfunk-host service install`. - packaging/windows/punktfunk-host.iss: lay exe into Program Files, optional SudoVDA driver task, run service install/start; [Code] stops+waits the service before file copy on upgrade; uninstall runs service uninstall. - pack-host-installer.ps1: cert (reuses MSIX_CERT_PFX_B64 / self-signed CN=unom), sign inner exe + setup.exe, fetch/stage SudoVDA, run ISCC, export public .cer. - fetch-sudovda.ps1 / install-sudovda.ps1: pinned SudoVDA + nefcon download, cert import, gated device-node create (no phantom dup), pnputil install (warn-not-abort). - nvenc/: synthesize nvencodeapi.lib via llvm-dlltool from a 2-export .def so --features nvenc links with no GPU/SDK at build time. - .gitea/workflows/windows-host.yml: build (nvenc) -> clippy -> ISCC -> sign -> publish setup.exe + .cer to the generic registry pkg punktfunk-host-windows. Tag host-win-v* -> X.Y.Z (+ latest/ alias); main push -> rolling 0.2.<run>. - setup-windows-runner.ps1: provision Inno Setup; docs: installer instructions. SudoVDA/nefcon release URLs+SHA-256s in fetch-sudovda.ps1 are placeholders (baseline v0.2.1) — fetch warns + prints the computed hash until pinned. Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
79 lines
4.0 KiB
PowerShell
79 lines
4.0 KiB
PowerShell
<#
|
|
.SYNOPSIS
|
|
Install the bundled SudoVDA virtual-display driver. Runs ELEVATED at setup time (invoked from the
|
|
installer's [Run] section). Best-effort: warns and exits 0 on any failure — the host degrades to a
|
|
physical display without SudoVDA, so a driver hiccup must never abort the whole install.
|
|
|
|
.DESCRIPTION
|
|
-Dir holds the staged payload from fetch-sudovda.ps1 (the .inf/.cat/.dll + signing .cer + nefconc.exe).
|
|
Steps:
|
|
1. Trust the self-signed driver cert (machine Root + TrustedPublisher) so PnP installs it silently.
|
|
2. Create the root device node IF ABSENT (gated — a blind re-create spawns a phantom duplicate, and
|
|
the host's open_device() binds interface index 0; crates/punktfunk-host/src/vdisplay/sudovda.rs).
|
|
3. Stage + bind the driver (pnputil /add-driver /install — modern, in-box, idempotent).
|
|
|
|
Class/ClassGuid are read from the .inf so they always match the shipped driver.
|
|
|
|
.EXAMPLE
|
|
powershell -ExecutionPolicy Bypass -File install-sudovda.ps1 -Dir C:\path\to\sudovda
|
|
#>
|
|
[CmdletBinding()]
|
|
param(
|
|
[string]$Dir = $PSScriptRoot,
|
|
[string]$HardwareId = 'root\sudomaker\sudovda' # verified live (docs/windows-host.md)
|
|
)
|
|
# Never abort the installer on a driver failure.
|
|
$ErrorActionPreference = 'Continue'
|
|
trap { Write-Warning "SudoVDA install error: $_"; exit 0 }
|
|
|
|
function Test-SudoVdaPresent {
|
|
$devs = Get-PnpDevice -Class Display -PresentOnly -ErrorAction SilentlyContinue
|
|
foreach ($d in $devs) {
|
|
$hw = (Get-PnpDeviceProperty -InstanceId $d.InstanceId -KeyName 'DEVPKEY_Device_HardwareIds' `
|
|
-ErrorAction SilentlyContinue).Data
|
|
if ($hw -and ($hw | Where-Object { $_ -ieq $HardwareId })) { return $true }
|
|
}
|
|
return $false
|
|
}
|
|
|
|
$inf = Get-ChildItem -Path $Dir -Filter *.inf -Recurse -ErrorAction SilentlyContinue | Select-Object -First 1
|
|
$cer = Get-ChildItem -Path $Dir -Filter *.cer -Recurse -ErrorAction SilentlyContinue | Select-Object -First 1
|
|
$nef = Get-ChildItem -Path $Dir -Filter 'nefconc.exe' -Recurse -ErrorAction SilentlyContinue | Select-Object -First 1
|
|
if (-not $inf) { Write-Warning "no SudoVDA .inf in $Dir; skipping driver install."; exit 0 }
|
|
Write-Host "SudoVDA inf: $($inf.FullName)"
|
|
|
|
# 1) Trust the self-signed driver cert (a self-signed driver needs the cert in BOTH the machine
|
|
# Root store, so the chain validates, and TrustedPublisher, so PnP installs without a prompt).
|
|
if ($cer) {
|
|
Write-Host "==> importing $($cer.Name) to Root + TrustedPublisher"
|
|
certutil.exe -addstore -f Root "$($cer.FullName)" | Out-Null
|
|
certutil.exe -addstore -f TrustedPublisher "$($cer.FullName)" | Out-Null
|
|
}
|
|
else { Write-Warning "no .cer in $Dir — driver may not install silently (untrusted publisher)" }
|
|
|
|
# 2) Create the root device node only if it isn't already there.
|
|
if (Test-SudoVdaPresent) {
|
|
Write-Host "SudoVDA device node already present — leaving it as-is."
|
|
}
|
|
elseif ($nef) {
|
|
$infText = Get-Content -Raw $inf.FullName
|
|
$classGuid = ([regex]::Match($infText, '(?im)^\s*ClassGuid\s*=\s*(\{[0-9A-Fa-f-]+\})')).Groups[1].Value
|
|
$className = ([regex]::Match($infText, '(?im)^\s*Class\s*=\s*([^\s;]+)')).Groups[1].Value
|
|
if (-not $classGuid) { $classGuid = '{4d36e968-e325-11ce-bfc1-08002be10318}'; $className = 'Display' } # Display class
|
|
Write-Host "==> nefconc --create-device-node hwid=$HardwareId class=$className $classGuid"
|
|
& $nef.FullName --create-device-node --hardware-id $HardwareId --class-name $className --class-guid $classGuid
|
|
if ($LASTEXITCODE -ne 0 -and $LASTEXITCODE -ne 3010) {
|
|
Write-Warning "nefconc --create-device-node returned $LASTEXITCODE"
|
|
}
|
|
}
|
|
else { Write-Warning "nefconc.exe not found in $Dir — cannot create the SudoVDA device node." }
|
|
|
|
# 3) Stage + bind the driver (idempotent; re-staging the same .inf is harmless).
|
|
Write-Host "==> pnputil /add-driver $($inf.Name) /install"
|
|
& pnputil.exe /add-driver "$($inf.FullName)" /install
|
|
$rc = $LASTEXITCODE
|
|
if ($rc -eq 3010) { Write-Host " driver installed; a reboot is recommended." }
|
|
elseif ($rc -ne 0) { Write-Warning "pnputil /add-driver returned $rc" }
|
|
|
|
exit 0
|