enricobuehler 8b37badae4 docs(security): record measured WDA_EXCLUDEFROMCAPTURE behavior + capture-vs-viewer framing
Tested on .173: a WDA_EXCLUDEFROMCAPTURE window (affinity readback 0x11,
confirmed active) is pixel-identically visible in the punktfunk/1 stream
across no-flag / flag-set / flag-cleared phases — the flag makes no
difference to a present-tap capture. Replace the "untested, treat as
expected" note in the IDD-push residual list with the measured result,
and correct the framing: WDA visibility matches what a person at the
screen sees (it exceeds an ordinary capture tool, not the physical
viewer).

Add the matching public-facing paragraph to the security page covering
both asymmetries — WDA windows appear (same as a physical viewer), DRM
video is blanked (less than a physical viewer) — tied back to the page's
"a client sees what someone at the machine sees" model.

Co-Authored-By: Claude Fable 5 <noreply@anthropic.com>
2026-07-04 11:16:18 +00:00
..