Files
punktfunk/crates/punktfunk-host
enricobuehler 61c02e695e refactor(windows-host): OwnedHandle for the SCM STOP/SESSION events (Goal-3, last unsafe reduction)
The service's STOP/SESSION manual-reset events were smuggled across the C SCM
control-handler boundary as raw `isize` in `AtomicIsize` statics (the handler is a
capture-free `'static` closure, so it can't hold a non-`Send` `HANDLE` — it has to
reach the events through statics), reconstructed via `load_event`, and explicitly
`CloseHandle`d at `run_service` end.

Replace the raw-`isize` statics with `OnceLock<OwnedHandle>`:
- `run_service` creates each event, wraps it in an `OwnedHandle`, derives a borrowed
  `HANDLE` for `supervise` (unchanged signature), and `set`s the OnceLock (once per
  process) — all BEFORE the handler is registered, so the handler always sees `Some`.
- The handler reads `event_handle(&STOP_EVENT)` (a borrow) and `SetEvent`s it, with a
  defensive `None` guard (matches the old `SetEvent(HANDLE(0))` no-op if it ever fired
  pre-init).
- The events are owned by the OnceLocks for the process lifetime (the service process
  exits right after `run_service` returns, so the OS reaps them at exit). Dropping the
  explicit `CloseHandle` also removes the latent close-then-signal window the old
  statics had (the raw isize lingered after the close).

Deletes the `AtomicIsize`/`Ordering` import + `load_event` + the raw-isize smuggle —
the last host-side raw-handle reduction. Behaviour-preserving (same events, same
signal/wait/reset, same once-per-process init order). Linux check + fmt clean; the
file is #[cfg(windows)] → to be box-validated (compile + a service stop/restart).

Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-06-26 07:22:46 +00:00
..