fix(packaging/windows): Windows 11 22H2 floor + tray install task + stale console-port fixes
The OS floor is now enforced at install time (MinVersion=10.0.22621 with an explanatory [Messages] override): pf-vdisplay is built against IddCx 1.10, and on Windows 10 (incl. LTSC) / Win11 21H2 the device fails start with Code 10 STATUS_DEVICE_POWER_FAILURE (field-reported). Docs (site requirements/install/ windows-host pages + README) state the floor; new docs-site Security page. Installer also gains the trayicon task (punktfunk-tray.exe file + HKLM Run key, post-install launch as the signed-in user, upgrade taskkill + uninstall --quit/taskkill choreography before file deletion), and the wizard/cleanup text/port sweeps move off the stale :3000 web-console references to :47992 (cleanups sweep both for upgrades from old installs). Co-Authored-By: Claude Fable 5 <noreply@anthropic.com>
This commit is contained in:
@@ -85,7 +85,12 @@ DefaultGroupName=punktfunk
|
||||
DisableProgramGroupPage=yes
|
||||
UsePreviousAppDir=yes
|
||||
PrivilegesRequired=admin
|
||||
MinVersion=10.0
|
||||
; HARD floor: Windows 11 22H2 (build 22621). The pf-vdisplay driver is built against IddCx 1.10
|
||||
; (HDR *2 DDIs + FP16 caps, no runtime downgrade) — on anything older (all of Windows 10 incl.
|
||||
; LTSC, Windows 11 21H2) the driver package installs but the device fails to start with Code 10
|
||||
; STATUS_DEVICE_POWER_FAILURE, and the host can't stream. Gate the install instead; the message
|
||||
; is customized in [Messages] below.
|
||||
MinVersion=10.0.22621
|
||||
ArchitecturesAllowed=x64
|
||||
ArchitecturesInstallIn64BitMode=x64
|
||||
OutputDir={#OutputDir}
|
||||
@@ -113,6 +118,12 @@ UninstallDisplayIcon={app}\punktfunk.ico
|
||||
[Languages]
|
||||
Name: "english"; MessagesFile: "compiler:Default.isl"
|
||||
|
||||
[Messages]
|
||||
; Shown when MinVersion rejects the OS — name the actual requirement instead of Inno's generic
|
||||
; "requires Windows version 10.0.22621" (users on Windows 10 LTSC hit this; see the pf-vdisplay
|
||||
; IddCx 1.10 note at MinVersion above).
|
||||
WinVersionTooLowError=punktfunk host requires Windows 11 22H2 (build 22621) or newer.%n%nIts virtual display driver needs the IddCx 1.10 framework, which is not available on older Windows — including all editions of Windows 10 (LTSC too) and Windows 11 21H2.
|
||||
|
||||
[Tasks]
|
||||
#ifdef WithDriver
|
||||
Name: "installdriver"; Description: "Install the pf-vdisplay virtual display driver (required for native-resolution streaming)"
|
||||
@@ -134,9 +145,16 @@ Name: "installhdrlayer"; Description: "Install the HDR Vulkan layer (lets Vulkan
|
||||
; host (the common Windows setup); unchecked = the secure native-only host (punktfunk clients only).
|
||||
Name: "gamestream"; Description: "Enable GameStream (Moonlight) compatibility - lets stock Moonlight clients connect (uses legacy plain-HTTP pairing; for trusted LANs)"
|
||||
Name: "startservice"; Description: "Start the punktfunk host service now (also starts on every boot)"
|
||||
; The per-user status tray (punktfunk-tray.exe): shows running/stopped/failed at a glance and
|
||||
; offers open-console / start / stop / restart without a terminal. HKLM Run = every user who signs
|
||||
; in to this host box gets one (each session keeps exactly one via a Local\ mutex).
|
||||
Name: "trayicon"; Description: "Show the punktfunk status icon in the notification area at sign-in"
|
||||
|
||||
[Files]
|
||||
Source: "{#BinDir}\punktfunk-host.exe"; DestDir: "{app}"; Flags: ignoreversion
|
||||
; The status tray companion (windows-subsystem, embeds its own icons). Installed unconditionally
|
||||
; (small); only STARTED/registered when the trayicon task is selected.
|
||||
Source: "{#BinDir}\punktfunk-tray.exe"; DestDir: "{app}"; Flags: ignoreversion
|
||||
Source: "{#HostEnv}"; DestDir: "{app}"; Flags: ignoreversion
|
||||
Source: "{#Readme}"; DestDir: "{app}"; DestName: "README.txt"; Flags: ignoreversion
|
||||
; The branded icon, referenced by UninstallDisplayIcon (Apps & features shows it for the entry).
|
||||
@@ -184,6 +202,10 @@ Source: "{#VkLayerDir}\pf_vkhdr_layer.json"; DestDir: "{app}\vklayer"; Flags: ig
|
||||
#endif
|
||||
|
||||
[Registry]
|
||||
; Auto-start the status tray at sign-in (all users of this host box; uninsdeletevalue removes it
|
||||
; with the app). Operators who moved --mgmt-bind can append --mgmt-addr/--mgmt-port here.
|
||||
Root: HKLM64; Subkey: "SOFTWARE\Microsoft\Windows\CurrentVersion\Run"; ValueType: string; \
|
||||
ValueName: "PunktfunkTray"; ValueData: """{app}\punktfunk-tray.exe"""; Flags: uninsdeletevalue; Tasks: trayicon
|
||||
#ifdef WithVkLayer
|
||||
; Register the HDR Vulkan implicit layer system-wide. The 64-bit Vulkan loader reads
|
||||
; HKLM64\SOFTWARE\Khronos\Vulkan\ImplicitLayers; the value NAME is the manifest path and the DWORD
|
||||
@@ -222,12 +244,22 @@ Filename: "{app}\punktfunk-host.exe"; Parameters: "service start"; WorkingDir: "
|
||||
#ifdef WithWeb
|
||||
; Provision the console AFTER the host service is up (so the mgmt token exists): write the ACL'd
|
||||
; login password, register the PunktfunkWeb scheduled task (boot, SYSTEM, restart-on-failure),
|
||||
; open TCP 3000, and start it. {code:WebSetupParams} appends -PasswordFile only on a fresh install.
|
||||
; open TCP 47992, and start it. {code:WebSetupParams} appends -PasswordFile only on a fresh install.
|
||||
Filename: "{app}\punktfunk-host.exe"; Parameters: "web setup {code:WebSetupParams}"; WorkingDir: "{app}"; \
|
||||
StatusMsg: "Setting up the punktfunk web console..."; Flags: runhidden waituntilterminated
|
||||
#endif
|
||||
; Launch the status tray as the SIGNED-IN user (not the elevated install user) right away, so the
|
||||
; icon appears without waiting for the next sign-in.
|
||||
Filename: "{app}\punktfunk-tray.exe"; Flags: runasoriginaluser nowait skipifsilent; Tasks: trayicon
|
||||
|
||||
[UninstallRun]
|
||||
; Quit the tray FIRST - it is this exe being deleted, so it must not be running. --quit closes the
|
||||
; current session's instance (an elevated caller may message a medium-IL window; UIPI only blocks
|
||||
; low->high); the taskkill then reaps instances in OTHER signed-in sessions. [UninstallRun] runs
|
||||
; before file deletion, so a raced survivor only means a delete-on-reboot leftover, nothing worse.
|
||||
; (runasoriginaluser is not valid in [UninstallRun] - both entries run elevated, which is fine.)
|
||||
Filename: "{app}\punktfunk-tray.exe"; Parameters: "--quit"; Flags: runhidden waituntilterminated; RunOnceId: "PunktfunkTrayQuit"
|
||||
Filename: "{sys}\taskkill.exe"; Parameters: "/F /IM punktfunk-tray.exe"; Flags: runhidden waituntilterminated; RunOnceId: "PunktfunkTrayKill"
|
||||
Filename: "{app}\punktfunk-host.exe"; Parameters: "service uninstall"; Flags: runhidden waituntilterminated; RunOnceId: "PunktfunkHostServiceUninstall"
|
||||
; Remove the punktfunk drivers we installed (pf-vdisplay devnode + driver package, then the gamepad
|
||||
; driver packages). AFTER service uninstall so the host no longer holds the devices. Unconditional
|
||||
@@ -241,7 +273,7 @@ Filename: "{app}\punktfunk-host.exe"; Parameters: "driver uninstall --gamepad";
|
||||
; Stop + remove the PunktfunkWeb task and its firewall rule (leaves %ProgramData%\punktfunk config,
|
||||
; like the host uninstall does).
|
||||
Filename: "powershell.exe"; \
|
||||
Parameters: "-NoProfile -ExecutionPolicy Bypass -Command ""Stop-ScheduledTask -TaskName PunktfunkWeb -ErrorAction SilentlyContinue; Get-NetTCPConnection -LocalPort 3000 -State Listen -ErrorAction SilentlyContinue | ForEach-Object {{ Stop-Process -Id $_.OwningProcess -Force -ErrorAction SilentlyContinue }; Unregister-ScheduledTask -TaskName PunktfunkWeb -Confirm:$false -ErrorAction SilentlyContinue; Get-NetFirewallRule -DisplayName 'punktfunk web console (*' -ErrorAction SilentlyContinue | Remove-NetFirewallRule"""; \
|
||||
Parameters: "-NoProfile -ExecutionPolicy Bypass -Command ""Stop-ScheduledTask -TaskName PunktfunkWeb -ErrorAction SilentlyContinue; Get-NetTCPConnection -LocalPort 47992,3000 -State Listen -ErrorAction SilentlyContinue | ForEach-Object {{ Stop-Process -Id $_.OwningProcess -Force -ErrorAction SilentlyContinue }; Unregister-ScheduledTask -TaskName PunktfunkWeb -Confirm:$false -ErrorAction SilentlyContinue; Get-NetFirewallRule -DisplayName 'punktfunk web console (*' -ErrorAction SilentlyContinue | Remove-NetFirewallRule"""; \
|
||||
Flags: runhidden waituntilterminated; RunOnceId: "PunktfunkWebCleanup"
|
||||
#endif
|
||||
|
||||
@@ -300,7 +332,7 @@ begin
|
||||
FreshWebInstall := not FileExists(WebPasswordPath);
|
||||
WebPwPage := CreateInputQueryPage(wpSelectTasks,
|
||||
'Web console', 'Set the punktfunk web console login password',
|
||||
'The management console is served on http://this-computer:3000 and is login-gated. Keep the ' +
|
||||
'The management console is served on https://this-computer:47992 and is login-gated. Keep the ' +
|
||||
'secure password generated below (it is shown again on the final page) or enter your own - you ' +
|
||||
'can change it later in %ProgramData%\punktfunk\web-password.');
|
||||
WebPwPage.Add('Console password:', False); { visible, so the admin can read the generated default }
|
||||
@@ -329,7 +361,7 @@ procedure CurPageChanged(CurPageID: Integer);
|
||||
begin
|
||||
if (CurPageID = wpFinished) and FreshWebInstall then
|
||||
WizardForm.FinishedLabel.Caption := WizardForm.FinishedLabel.Caption + #13#10#13#10 +
|
||||
'Web console: http://<this-PC-IP>:3000' + #13#10 +
|
||||
'Web console: https://<this-PC-IP>:47992' + #13#10 +
|
||||
'Login password: ' + Trim(WebPwPage.Values[0]);
|
||||
end;
|
||||
|
||||
@@ -344,6 +376,17 @@ begin
|
||||
end;
|
||||
#endif
|
||||
|
||||
{ On upgrade a running tray locks punktfunk-tray.exe - kill every session's instance so the copy
|
||||
can overwrite it (the [Run] entry / next sign-in relaunches the new build). Best-effort; a fresh
|
||||
install is a no-op. }
|
||||
procedure StopTrays;
|
||||
var
|
||||
ResultCode: Integer;
|
||||
begin
|
||||
Exec(ExpandConstant('{sys}\taskkill.exe'), '/F /IM punktfunk-tray.exe', '',
|
||||
SW_HIDE, ewWaitUntilTerminated, ResultCode);
|
||||
end;
|
||||
|
||||
{ On upgrade the running service locks punktfunk-host.exe (and the supervisor would respawn it from
|
||||
the OLD binary), so stop it and WAIT for STOPPED before files are copied. Best-effort; a fresh
|
||||
install is a no-op (the service doesn't exist yet). }
|
||||
@@ -361,10 +404,11 @@ begin
|
||||
end;
|
||||
|
||||
#ifdef WithWeb
|
||||
{ Stop a running web console + free :3000 BEFORE the file copy, so the old server doesn't lock
|
||||
.output / web-run.cmd / bun.exe and the new task can bind. Killing the :3000 listener owner is
|
||||
runtime-agnostic (an early install may have run node, the current one runs bun). `web setup`
|
||||
repeats this idempotently after the copy. Best-effort; a fresh install is a no-op. }
|
||||
{ Stop a running web console + free its port BEFORE the file copy, so the old server doesn't lock
|
||||
.output / web-run.cmd / bun.exe and the new task can bind. Killing the listener owner is
|
||||
runtime-agnostic (an early install may have run node on :3000, the current one runs bun on
|
||||
:47992 - sweep both). `web setup` repeats this idempotently after the copy. Best-effort; a
|
||||
fresh install is a no-op. }
|
||||
procedure StopWebConsole;
|
||||
var
|
||||
ResultCode: Integer;
|
||||
@@ -373,7 +417,7 @@ begin
|
||||
'-NoProfile -ExecutionPolicy Bypass -Command "' +
|
||||
'$ErrorActionPreference=''SilentlyContinue''; ' +
|
||||
'Stop-ScheduledTask -TaskName PunktfunkWeb; ' +
|
||||
'Get-NetTCPConnection -LocalPort 3000 -State Listen | ForEach-Object { Stop-Process -Id $_.OwningProcess -Force }"',
|
||||
'Get-NetTCPConnection -LocalPort 47992,3000 -State Listen | ForEach-Object { Stop-Process -Id $_.OwningProcess -Force }"',
|
||||
'', SW_HIDE, ewWaitUntilTerminated, ResultCode);
|
||||
end;
|
||||
#endif
|
||||
@@ -383,6 +427,7 @@ begin
|
||||
if CurStep = ssInstall then
|
||||
begin
|
||||
StopHostServiceAndWait;
|
||||
StopTrays; { upgrade-safe: unlock punktfunk-tray.exe before the copy }
|
||||
#ifdef WithWeb
|
||||
StopWebConsole; { upgrade-safe: free :3000 + unlock the web files before the copy }
|
||||
{ Stash the chosen password for `web setup` (fresh install only); the temp copy is auto-cleaned. }
|
||||
|
||||