forked from unom/punktfunk
The IddCx driver declares `DISPLAYCONFIG_OUTPUT_TECHNOLOGY_HDMI` for its monitors
(`packaging/windows/drivers/pf-vdisplay/src/monitor.rs`, `IDDCX_MONITOR_INFO::MonitorType`),
and `output_tech_class`'s allowlist reads HDMI as a real external panel. So every consumer of
`target_inventory` counted OUR OWN virtual display among the operator's physical monitors.
Measured on .173: both targets came back `external_physical`, `[(4352, "LG TV SSCR2", HDMI),
(257, "punktfunk", HDMI)]`.
That is not cosmetic. `restore_displays_ccd` ends with the last-resort guarantee that the desk
is never left all-dark:
let (connected, lit) = target_inventory().filter(external_physical) …
if connected > 0 && lit == 0 { force_extend_topology() }
The restore runs BEFORE the virtual is REMOVEd, so our own still-active display kept `lit >= 1`
and the backstop could NEVER fire — in exactly the situation it was written for. It also made
our display a candidate "physical suspect" in the disturbance-attribution inventory, which
`TargetInventory`'s own doc rules out ("only indirect/virtual targets (our own IDD included)").
Targets carrying our EDID manufacturer id ("PNK", stamped by the driver's edid.rs) are now
classified `external_physical = false`, tech `punktfunk-virtual`. Matching on the monitor device
path rather than the friendly name — the path carries the manufacturer id the OS itself derived
— and on both spellings, since the CCD device-interface path uses `#`
(`\\?\DISPLAY#PNK0000#…`) while the PnP instance id for the same monitor uses `\`
(`DISPLAY\PNK0000\1&15ecd195&5&UID264`, observed on .173). Allowlist-shaped like
`output_tech_class`, so a third-party virtual display is never silently adopted.
ON GLASS, read-only, on .173 — and it caught the backstop's trigger live:
target 264 active=true external_physical=false tech=punktfunk-virtual "punktfunk"
target 4352 active=false external_physical=true tech=HDMI "LG TV SSCR2"
The physical is dark while our virtual holds the desktop. Post-fix that is `connected=1, lit=0`
— the backstop fires. Pre-fix it was `connected=2, lit=1` — suppressed. The new hardware case is
deliberately READ-ONLY (creates and destroys nothing) so it is safe against a live host;
repeated IddCx create/destroy churn is what wedges the driver's slot pool.
Also adds `manager::FAIL_NEXT_ISOLATES`, a `#[cfg(test)]` seam that fails the next N
`isolate_displays_ccd` calls, with every call site in manager.rs routed through it. The Phase-3
recovery legs fire only on a failed isolate, which real hardware does not produce, so they
cannot otherwise be exercised. `#[cfg(test)]` rather than an env knob: this crate's live tests
compile under `cfg(test)`, so no production switch exists that could disable display isolation
on an operator's box. The §5 3.2 case built on it is included but is NOT yet a passing on-glass
result — see the plan for where it got to.
Verified on .173: clippy -p punktfunk-host -p pf-vdisplay --all-targets and -p pf-win-display
--all-targets clean; pf-vdisplay 56 pass, pf-win-display 2 pass + hardware cases; both xcheck
targets clean.