forked from unom/punktfunk
Field A/B (reporter, Legion 5 Pro hybrid, 2026-07-27): the ~2 s capture-stall metronome IS the exclusive isolate's own doing — deactivating the laptop panel leaves a dark-but-connected eDP head whose driver-level servicing disturbs the capture path (~1.7-2.8 s period); `topology: primary` (panel stays active) stopped it outright (16.3 stalls/min → 0). Our own .221 logged the identical signature the day before. The detector then steered AWAY from the cause: connected_inactive filtered to EXTERNAL physicals only, so the one display that mattered — on a hybrid laptop, the default config — reported as `none`. - TargetInventory: new `internal_panel` class bit (eDP/LVDS/embedded). - connected_inactive_externals → connected_inactive_physicals: internal panels join the suspect list (virtual/indirect stay excluded); a nameless panel renders as "laptop panel". - The below-OS METRONOMIC warn names the dark-panel case and its actual cures (`topology: primary`, `pnp_disable_monitors`) — the old text's "unplug it" prescriptions are impossible for an internal panel. - ddc_power_off: a zero-ack sweep now says at INFO that the axis did nothing (internal panels have no DDC/CI) instead of silently no-op'ing. Co-Authored-By: Claude Fable 5 <noreply@anthropic.com>