forked from unom/punktfunk
Still -1 on glass. The message was going out; the client was ignoring it. Which packet-type table a client reads is decided by exactly one thing — moonlight-common-c sets `encryptedControlStream = APP_VERSION_AT_LEAST(7, 1, 431)` — and we advertise 7.1.431, so every client reads the ENCRYPTED table, where termination is 0x0109. We were sending 0x0100. Deriving that from the nonce scheme was the error: `NonceKind` describes how the GCM nonce is built and nothing else. The two look like the same "is this encrypted" axis and are not. The HDR message could never have caught it either, since 0x010e is identical in both tables — so the only symptom was the silence this whole chain has been about. Pinned with a test asserting APP_VERSION still clears 7.1.431, because if it ever drops below, the correct type silently becomes 0x0100 again and the stream goes back to ending as an error with nothing failing to explain why. .133: 281 passed (+3), same 4 environmental native::tests failures. The Linux box is off the network, so the full Linux suite is owed.